feat!: treat energy site ids as int, signal number support via X-Library (#49)
Tesla returns energy site ids as JSON numbers; this library previously
forced them to strings throughout. site_id is now int end to end:
get_energysite(str | int) normalises via int(...), energysites is keyed
by int, and event matching casts the incoming site_id/id to int so it
matches whether the api sends a string or a number.
The api tells clients apart by the X-Library header: the legacy value
"python teslemetry-stream" keeps getting strings, anything with a
"/<version>" suffix (read from installed package metadata) opts into
numbers.
BREAKING CHANGE: TeslemetryStreamEnergySite.site_id is now int, not str.
Consumers comparing it against a string will need to update.
Copy file name to clipboardExpand all lines: AGENTS.md
+3-1Lines changed: 3 additions & 1 deletion
Display the source diff
Display the rich diff
Original file line number
Diff line number
Diff line change
@@ -43,6 +43,7 @@ Project-intrinsic knowledge that should travel with the code: build, test, relea
43
43
-`site_info` does **not** carry `tariff_content`/`tariff_content_v2`. The V2 tariff is its own event/listener (`listen_TariffContentV2`), same envelope shape, with a `None` body meaning explicit server-side removal rather than "not received yet".
44
44
- All of these share a silence-means-no-change contract: the server sends a connect-time snapshot and then fires only on change. Freshness lives in REST, never in event cadence.
45
45
- There is deliberately no helper recombining `site_info` and `tariff_content_v2` - it would only ever cover V2 (legacy V1 `tariff_content` has no SSE topic and stays REST-only). A consumer wanting both tariffs uses the REST site_info endpoint.
46
+
- Site ids are `int` throughout, matching Tesla's own JSON-number representation: `get_energysite(site_id: str | int)` normalises via `int(...)` (raising `ValueError` on a non-numeric id), `TeslemetryStream.energysites` is keyed by int, `TeslemetryStreamEnergySite.site_id` is an int, and every site-id/`Key.ID` comparison in `energysite.py` casts the incoming event value with `int(...)` before comparing - so an event carrying either a string or a number matches. The `X-Library` header's `/<version>` suffix (`stream.py`, read from installed package metadata) is the api's signal that this client accepts numeric ids; the bare legacy value means string-only.
46
47
47
48
## Test map
48
49
@@ -58,8 +59,9 @@ Project-intrinsic knowledge that should travel with the code: build, test, relea
58
59
|`str` payload coercion against real telemetry |`test_field_type_coercion.py`|
Create an energy site object to create listeners for `live_status` and `site_info`.
263
+
Create an energy site object to create listeners for `live_status` and `site_info`. Accepts a str or int; the returned object's `site_id` is always normalized to `int`.
264
264
265
265
### `connected -> bool`
266
266
Return if connected.
@@ -346,7 +346,7 @@ A full list of fields and metadata can be found at [api.teslemetry.com/fields.js
346
346
347
347
## Public Methods in TeslemetryStreamEnergySite Class
0 commit comments