Skip to content

About

Portable Modbus TCP server for STM32 Cortex-M4 with lwIP support, tests, and Make/CMake builds.

Resources

Stars

0 stars

Watchers

1 watching

Forks

Repository files navigation

STM32 Modbus TCP Server

STM32 Modbus TCP Server for Cortex‑M4

A compact Modbus implementation written in portable C11, with an STM32/lwIP raw-API TCP transport, host-tested Modbus RTU slave and master ADU cores, serial-line-only RTU diagnostics and FC11 Server ID reporting, a portable RTU master transaction engine with deterministic timeouts and retries, a deterministic in-memory register map, fixed-capacity application file records with read/write support, application-owned FIFO queue snapshots, a bounded application-configurable FC43 MEI transport registry, strict request validation, and no heap allocation in the request path.

The repository builds and tests on a normal Linux/macOS development machine. The RTU slave layer validates complete frames, provides single-byte receive and fixed 50 microsecond timing entry points, detects T1.5/T3.5 boundaries, and reuses the same PDU engine as TCP. The separate RTU master core builds complete requests and validates complete responses without depending on hardware. The portable master transaction engine adds one-outstanding-request state management, response deadlines, retry delays, transport-completion/error events, broadcast completion, and bounded diagnostics. UART receive framing, board-specific UART/timer glue, RS-485 direction control, and CubeMX integration remain separate.

Build status

The default build verifies all portable code and compile-checks the lwIP transport against API-compatible headers:

make
make test

make test runs:

  • Modbus CRC-16 known-vector and corruption tests
  • direct C unit tests for the shared Modbus PDU engine
  • host tests for the Modbus RTU ADU wrapper, addressing, CRC, and broadcasts
  • host tests for RTU master request builders, response validation, exceptions, and decoding
  • host tests for RTU master transaction state, deadlines, retries, transport events, broadcast handling, and diagnostics
  • dedicated FC07/FC08/FC0B/FC0C slave, master, event-log, policy, listen-only, transaction, and TCP-rejection tests
  • dedicated FC11 configuration, RTU-only dispatch, master, transaction, maximum-size, and TCP-rejection tests
  • dedicated FC20, FC21, FC22, FC23, FC24, FC43 generic-MEI, and FC43/14 shared-PDU, TCP, RTU, master, transaction, boundary, and malformed-frame tests
  • fake-timer tests for T1.5/T3.5, buffering, overflow, recovery, and transmit dispatch
  • C unit tests for the register map and Modbus TCP ADU wrapper
  • the on-device register self-test as a host executable
  • strict -Wall -Wextra -Wpedantic -Wconversion -Wsign-conversion -Wshadow -Werror compile checks
  • a real TCP socket integration test against the included POSIX demo server

A GitHub Actions workflow and a Docker build are included.

Architecture

Layered project architecture

The design separates the shared PDU engine from transport framing and network I/O:

  • mb_process_pdu() dispatches shared function codes, including FC20 Read File Record, FC21 Write File Record, FC22 Mask Write Register, FC23 Read/Write Multiple Registers, FC24 Read FIFO Queue, generic FC43 Encapsulated Interface Transport, and FC43/14 Read Device Identification, and creates normal or exception response PDUs without TCP-specific framing.
  • mbtcp_process_adu() validates MBAP fields, invokes the shared PDU API, and builds the Modbus TCP response ADU.
  • mbrtu_process_adu() preserves the ordinary-function RTU path and adds an opt-in RTU-only FC11 dispatcher, while mbrtu_process_adu_with_diagnostics() adds FC07, FC08, FC0B, and FC0C.
  • mbrtum_build_*_request() creates complete RTU master requests, including FC11, FC20, FC21, FC22, FC23, FC24, generic FC43, and FC43/14; the diagnostics builders and request-ADU-aware validator add strict FC07/FC08/FC0B/FC0C master support.
  • mbrtum_transaction_*() owns one active request, drives asynchronous transmit/wait/retry states, enforces wrap-safe deadlines, reuses the complete-frame master validator, and exposes bounded diagnostics.
  • mbrtu_on_rx_byte_isr() and mbrtu_on_50us_tick_isr() assemble frames with minimal interrupt work; mbrtu_poll() processes and transmits them from the main loop.
  • mb_crc16() implements the Modbus serial-line CRC-16 with low-byte-first wire order.
  • modbus_tcp.c handles lwIP TCP callbacks, fragmented/coalesced stream data, client slots, and response transmission.
  • modbus.c provides the default fixed-size coils and register banks.
  • weak write hooks connect Modbus writes to relays, PWM, configuration storage, or other application logic.

Supported function codes

Function Code Maximum per request Transport
Read Coils 0x01 2,000 bits TCP and RTU
Read Discrete Inputs 0x02 2,000 bits TCP and RTU
Read Holding Registers 0x03 125 registers TCP and RTU
Read Input Registers 0x04 125 registers TCP and RTU
Write Single Coil 0x05 1 bit TCP and RTU
Write Single Register 0x06 1 register TCP and RTU
Read Exception Status 0x07 1 status byte RTU only
Diagnostics 0x08 Up to 250 data bytes RTU only
Get Communication Event Counter 0x0B Fixed response RTU only
Get Communication Event Log 0x0C 64 event bytes RTU only
Report Server ID 0x11 251 response-data bytes RTU only
Write Multiple Coils 0x0F 1,968 bits TCP and RTU
Write Multiple Registers 0x10 123 registers TCP and RTU
Read File Record 0x14 35 subrequests; 245 response-data bytes TCP and RTU
Write File Record 0x15 27 subrequests; 251 request-data bytes TCP and RTU
Mask Write Register 0x16 1 holding register TCP and RTU
Read/Write Multiple Registers 0x17 Read 125, write 121 registers TCP and RTU
Read FIFO Queue 0x18 31 queued registers TCP and RTU
Encapsulated Interface Transport 0x2B 251 interface bytes TCP and RTU
Read Device Identification 0x2B / 0x0E Segmented object list TCP and RTU

Illegal functions, addresses, quantities, byte counts, and values produce standard Modbus exception responses. Serial-line-only diagnostics and FC11 are deliberately absent from the Modbus TCP dispatcher and return Illegal Function over TCP.

FC11 reports an application-configured, device-specific Server ID of 1–250 bytes, a 0x00/0xFF run status, and optional copied Additional Data. The combined response-data length is bounded at 251 bytes. FC11 is dispatched exclusively by the RTU layer. See docs/modbus-fc11-report-server-id.md.

FC20 reads one or more sequential ranges from application-owned file-record arrays. The fixed-capacity descriptor map supports sparse file numbers without copying or dynamically allocating record storage. See docs/modbus-fc20-read-file-record.md for the storage API, wire format, master validation, and limits.

FC21 writes one or more sequential ranges in the same application-owned file arrays. The complete request is validated before any record is modified, the normal response exactly echoes the request, and RTU broadcast writes are supported without a response. See docs/modbus-fc21-write-file-record.md.

FC22 atomically combines one holding register with an AND mask and an OR mask, returns an exact request echo for unicast requests, and supports RTU broadcast writes without a response. See docs/modbus-fc22-mask-write-register.md.

FC23 performs its write before its read, including when the ranges overlap. The shared PDU implementation validates the entire request and normal-response capacity before applying any write. See docs/modbus-fc23.md for the wire format, limits, master API, transport behavior, and test coverage.

FC24 reads a non-destructive snapshot from an application-owned FIFO register block. The response includes a two-byte Byte Count, FIFO Count, and up to 31 queued register values. See docs/modbus-fc24-read-fifo-queue.md for the configuration API, exception rules, master decoding, and tests.

FC43 generic Encapsulated Interface Transport provides a fixed-capacity application handler registry for bounded [0x2B][MEI type][MEI data] requests and responses. MEI 0x0D CANopen is intentionally unsupported, MEI 0x0E continues to use the built-in strict Device Identification implementation, and all other types are disabled until explicitly registered. See docs/modbus-fc43-mei-transport.md.

FC43/14 uses fixed-capacity application-configured identification objects, including mandatory Basic objects, optional Regular objects, and private Extended objects. Stream responses segment only at object boundaries and use More Follows plus Next Object ID for deterministic pagination. See docs/modbus-fc43-device-identification.md.

Repository layout

App/
├── include/
│   ├── modbus.h              Register-map API and write hooks
│   ├── modbus_device_id.h    Fixed-capacity FC43/14 object configuration
│   ├── modbus_file_record.h  Fixed-capacity application file-record map
│   ├── modbus_fifo.h         Fixed-capacity FC24 FIFO descriptor map
│   ├── modbus_mei.h          Generic FC43 handler registration API
│   ├── modbus_pdu.h          Shared transport-independent PDU API
│   ├── modbus_protocol.h     Backward-compatible Modbus TCP ADU API
│   ├── modbus_crc16.h        Portable Modbus serial CRC-16 API
│   ├── modbus_rtu.h          RTU ADU plus byte/timing server API
│   ├── modbus_rtu_diagnostics.h
│   │                          Fixed-capacity serial diagnostics API
│   ├── modbus_rtu_server_id.h
│   │                          Fixed-capacity FC11 configuration API
│   ├── modbus_rtu_master.h   Complete-frame RTU master API
│   ├── modbus_rtu_master_transaction.h
│   │                          Portable master timeout/retry transaction API
│   ├── modbus_tcp.h          lwIP server API
│   └── platform_port.h       Compile-time configuration
└── src/
    ├── modbus.c              Coils, registers, Device ID, and file-map state
    ├── modbus_device_id_internal.h
    │                          Internal FC43/14 PDU integration helper
    ├── modbus_file_record_internal.h
    ├── modbus_fifo_internal.h
    │                          Internal FC24 PDU integration helper
    ├── modbus_mei_internal.h
    │                          Internal generic FC43 dispatch helper
    ├── modbus_protocol.c     Shared PDU engine and TCP ADU wrapper
    ├── modbus_crc16.c        Table-free Modbus CRC-16 implementation
    ├── modbus_rtu.c          RTU ADU and bare-metal timing state machine
    ├── modbus_rtu_diagnostics.c
    │                          FC07/FC08/FC0B/FC0C RTU-only state and dispatch
    ├── modbus_rtu_server_id.c
    │                          FC11 RTU-only state and dispatch
    ├── modbus_rtu_server_id_internal.h
    │                          Internal FC11 dispatch helper
    ├── modbus_rtu_master.c   Complete-frame RTU master core
    ├── modbus_rtu_master_transaction.c
    │                          Portable master transaction state machine
    ├── modbus_tcp.c          lwIP raw-API transport
    └── platform_stm32.c      HAL tick and optional RTOS locking

Examples/
├── posix_server.c            Local functional demo
├── stm32_cube_main.c         CubeMX integration reference
└── STM32F767_RTU_Master/    FC01-FC04 hardware-validated STM32F767 example

Tests/
├── host/                     Unit, transaction, and socket-level tests
│   ├── test_modbus_fc11.c    Dedicated FC11 RTU/master/TCP-boundary tests
│   ├── test_modbus_fc20.c    Dedicated FC20 file/RTU/TCP/master tests
│   ├── test_modbus_fc21.c    Dedicated FC21 write/echo/broadcast tests
│   ├── test_modbus_fc22.c    Dedicated FC22 mask/echo/broadcast tests
│   ├── test_modbus_fc24.c    Dedicated FC24 FIFO/TCP/RTU/master tests
│   ├── test_modbus_fc23.c    Dedicated FC23 shared/RTU/TCP/master tests
│   └── test_modbus_fc43_device_id.c
│                              Dedicated FC43/14 object and transport tests
├── mocks/lwip/               Compile-check headers only
└── stm32/                    Register-map self-test for a target board

docs/
├── modbus-fc11-report-server-id.md
├── modbus-fc20-read-file-record.md
├── modbus-fc21-write-file-record.md
├── modbus-fc22-mask-write-register.md
├── modbus-fc23.md
├── modbus-fc24-read-fifo-queue.md
├── modbus-fc43-device-identification.md
├── modbus-rtu-core.md
├── modbus-rtu-master-core.md
├── modbus-rtu-master-transaction.md
├── modbus-rtu-diagnostics.md
├── modbus-rtu-timing.md
└── stm32f767-rtu-validation.md

Quick start on a development machine

Requirements: a C11 compiler, Make, and Python 3.

git clone <your-repository-url>
cd stm32-modbus-tcp-server
make test

Expected result:

modbus CRC-16 tests: PASS
modbus PDU tests: PASS
modbus RTU ADU tests: PASS
modbus RTU legacy source-list test: PASS
modbus RTU master tests: PASS
modbus RTU master transaction tests: PASS
modbus RTU diagnostics tests: PASS
Modbus FC11 Report Server ID tests: PASS
Modbus FC23 tests: PASS
Modbus FC43/14 device identification tests: PASS
Modbus FC43 generic MEI transport tests: PASS
Modbus FC20 Read File Record tests: PASS
Modbus FC21 Write File Record tests: PASS
Modbus FC22 Mask Write Register tests: PASS
Modbus FC24 Read FIFO Queue tests: PASS
modbus RTU timing tests: PASS
modbus protocol tests: PASS
Modbus SelfTest: total=5, passed=5, failed=0, first_err=0
Modbus TCP smoke test: PASS (127.0.0.1:15020)

CMake

cmake -S . -B build-cmake -DCMAKE_BUILD_TYPE=Release
cmake --build build-cmake --parallel
ctest --test-dir build-cmake --output-on-failure

Docker

docker build -t stm32-modbus-tcp .
docker run --rm stm32-modbus-tcp

Run the local Modbus TCP demo

The POSIX demo makes it possible to test the same protocol core before hardware is available. It listens on loopback only and defaults to unprivileged port 1502.

Terminal 1:

make demo
./build/modbus_posix_server 1502

Terminal 2:

python3 Tests/host/ci_modbus_smoke.py 127.0.0.1 1502

The smoke test writes and reads holding registers and coils, then verifies an illegal-address exception.

Use the portable Modbus RTU ADU core

The complete-frame RTU API can be used directly, or the portable bare-metal layer can turn UART byte events and a fixed 50 microsecond tick into complete frames.

An RTU request buffer has this layout:

slave address | function and data PDU | CRC low | CRC high

Include the ordinary RTU and CRC sources with the shared register/PDU sources:

App/src/modbus.c
App/src/modbus_protocol.c
App/src/modbus_crc16.c
App/src/modbus_rtu.c

This pre-diagnostics source list remains compile- and link-compatible. To enable the serial diagnostics slave path, also add App/src/modbus_rtu_diagnostics.c and define MBRTU_ENABLE_DIAGNOSTICS=1 for modbus_rtu.c and the diagnostics source. The repository Make and CMake builds set this definition automatically.

To enable FC11, also link App/src/modbus_rtu_server_id.c and define MBRTU_ENABLE_SERVER_ID=1. Configure the copied, variable-length Server ID, run status, and optional Additional Data with mbrtu_server_id_configure(). The pre-FC11 source list remains compile- and link-compatible when the optional source and definition are absent.

Example complete-frame processing:

#include "modbus_rtu.h"

uint8_t response[MODBUS_RTU_ADU_MAX_SIZE];
size_t response_len = 0u;

int result = mbrtu_process_adu(1u,
                               request,
                               request_len,
                               response,
                               sizeof(response),
                               &response_len);

if (result == MBRTU_RESPONSE_READY) {
    uart_transmit(response, response_len);
}

Behavior:

  • configured slave addresses must be 1 through 247
  • address 0 is broadcast
  • valid broadcast writes are applied without a response
  • broadcast reads, frames for another slave, invalid CRC frames, and invalid RTU lengths are silently ignored
  • normal and exception responses include a newly generated low-byte-first CRC
  • no dynamic allocation is used

Portable RTU diagnostics

Compile with MBRTU_ENABLE_DIAGNOSTICS=1, link App/src/modbus_rtu_diagnostics.c, and attach a caller-owned mbrtu_diagnostics_t with mbrtu_process_adu_with_diagnostics() or mbrtu_init_with_diagnostics() to enable FC07, FC08, FC0B, and FC0C. The state uses saturating 16-bit counters and a deterministic 64-byte newest-first event log. State-changing FC08 operations are denied unless an application policy callback explicitly approves them.

Listen-only and restart requests set portable pending-action flags; STM32 UART restart, watchdog handling, and RS-485 direction control remain application responsibilities. See docs/modbus-rtu-diagnostics.md for the complete API, counter rules, broadcast behavior, master builders, and tests.

Portable RTU master request and response core

The separate master core builds complete FC01, FC02, FC03, FC04, FC05, FC06, FC0F, FC10, FC11, FC20, FC21, FC22, FC23, FC24, and FC43/14 request ADUs and validates one complete response against the original request descriptor. It checks CRC, address, function, byte count, packed-bit padding, write acknowledgements, FC11 device-specific Server ID length and run-status data, FC20 subresponses, FC21 exact echoes, FC22 mask acknowledgements, FC23 read data, FC24 FIFO count/value data, generic FC43 MEI payloads, FC43/14 object lists, and Modbus exception responses.

The complete-frame master core intentionally does not own UART framing, response timeouts, retries, STM32 HAL integration, or RS-485 direction control. See docs/modbus-rtu-master-core.md for the public contract, examples, limits, validation rules, and next-stage boundary.

The byte/timing API adds single-byte receive events, a fixed 50 microsecond tick, T1.5/T3.5 frame detection, two-buffer ownership, overflow recovery, and main-loop transmission. See docs/modbus-rtu-timing.md for the complete contract and STM32 integration boundary.

Bare-metal byte and timing example

static mbrtu_context_t rtu;
static uint8_t rx_a[MODBUS_RTU_ADU_MAX_SIZE];
static uint8_t rx_b[MODBUS_RTU_ADU_MAX_SIZE];
static uint8_t response[MODBUS_RTU_ADU_MAX_SIZE];

const mbrtu_config_t config = {
    .slave_address = 1u,
    .baud_rate = 19200u,
    .data_bits = 8u,
    .parity_bits = 1u,
    .stop_bits = 1u,
    .receive_buffer_a = rx_a,
    .receive_buffer_b = rx_b,
    .receive_buffer_capacity = sizeof(rx_a),
    .response_buffer = response,
    .response_buffer_capacity = sizeof(response),
    .transmit = uart_transmit,
    .user_context = NULL
};

(void)mbrtu_init(&rtu, &config);

Call mbrtu_on_rx_byte_isr() for each received byte, call mbrtu_on_50us_tick_isr() every 50 microseconds, and call mbrtu_poll() regularly from the main loop. CRC calculation, function dispatch, application write hooks, and response transmission never run from the receive or timing ISR.

Modbus RTU T1.5 and T3.5 timing

STM32CubeMX integration

This repository intentionally does not ship fabricated board startup code, a linker script, PHY configuration, or Ethernet pin assignments. Those settings must match the selected STM32 and board.

1. Generate the board project

In STM32CubeMX or STM32CubeIDE:

  1. Select the exact MCU or development board.
  2. Enable Ethernet and configure the correct RMII/MII pins and PHY address.
  3. Enable lwIP.
  4. Select the lwIP raw API. The included transport does not require Netconn or BSD sockets.
  5. For a no-RTOS project, ensure the generated main loop calls MX_LWIP_Process().
  6. Generate the project with its HAL, CMSIS, startup, linker, Ethernet, and lwIP files.

2. Add the application sources

For Modbus TCP, add these files to the generated build:

App/src/modbus.c
App/src/modbus_protocol.c
App/src/modbus_tcp.c
App/src/platform_stm32.c

For the host-tested ordinary RTU ADU core, also add:

App/src/modbus_crc16.c
App/src/modbus_rtu.c

To enable the RTU diagnostics slave path, additionally add:

App/src/modbus_rtu_diagnostics.c

and define MBRTU_ENABLE_DIAGNOSTICS=1 in the active compiler configuration. Without that definition, the original RTU source list retains ordinary-function behavior and does not require the diagnostics source.

The portable receive/timing state machine is included. The STM32 UART interrupt, timer/SysTick setup, and HAL time-base preservation remain board-specific.

Add this include directory:

App/include

For a CubeIDE project, copy the App directory into the project, refresh the workspace, and ensure the source folder is not excluded from the active build configuration.

3. Initialize the server

Merge the relevant lines from Examples/stm32_cube_main.c into the generated main.c:

#include "modbus.h"
#include "modbus_tcp.h"

/* After MX_LWIP_Init(): */
mb_init();
mbtcp_init();

/* In a no-RTOS superloop: */
MX_LWIP_Process();
mbtcp_poll();

Initialize the server only after the Ethernet interface and lwIP are initialized.

4. Configure the data model

Edit App/include/platform_port.h or pass equivalent compiler definitions:

#define MBTCP_SERVER_PORT       502u
#define MBTCP_MAX_CLIENTS       3u
#define MB_MAX_COILS            256u
#define MB_MAX_DISCRETE_INPUTS  256u
#define MB_MAX_HREGS            256u
#define MB_MAX_IREGS            256u

Default Modbus register map

5. Connect writes to hardware

Override either weak hook in an application source file:

void mb_on_write_coil(uint16_t address, uint8_t value)
{
    if (address == 0u) {
        HAL_GPIO_WritePin(RELAY_GPIO_Port,
                          RELAY_Pin,
                          value != 0u ? GPIO_PIN_SET : GPIO_PIN_RESET);
    }
}

void mb_on_write_hreg(uint16_t address, uint16_t value)
{
    if (address == 0u) {
        set_pwm_duty(value);
    }
}

Update read-only values from the application:

mb_set_ireg(0u, adc_sample);
mb_set_dinput(0u, digital_input_state);

6. FreeRTOS locking

Define WITH_RTOS when multiple tasks access the map. platform_stm32.c then uses a FreeRTOS mutex. For stricter real-time requirements, create the mutex during application initialization and replace the default lazy initialization with your project’s synchronization policy.

TCP packet processing

Modbus TCP request and response flow

The lwIP transport supports:

  • TCP frames split across multiple pbufs or receive callbacks
  • multiple Modbus ADUs arriving in one TCP stream
  • a fixed maximum ADU of 260 bytes
  • up to MBTCP_MAX_CLIENTS active connections
  • no dynamic allocation by the application code

On-device self-test

Add these files to a temporary target build:

Tests/stm32/register_selftest.c
Tests/stm32/register_selftest.h

Then run:

MbSelfTestResult result;
char line[128];

mb_selftest_run(&result);
mb_selftest_print(line, sizeof(line), &result);
printf("%s", line);

The self-test exercises all four data banks, boundary behavior, and deterministic bulk patterns without requiring Ethernet.

Test a physical board

After flashing and assigning an IP address:

python3 Tests/host/ci_modbus_smoke.py 192.168.1.50 502

Or use a third-party Modbus client. Protocol addresses are zero-based in requests; some tools display holding register address 0 as 40001.

Useful Wireshark filters are in tools/wireshark_display_filter.md.

Memory use

With the default map sizes, data storage uses approximately:

  • 256 bytes for coils
  • 256 bytes for discrete inputs
  • 512 bytes for holding registers
  • 512 bytes for input registers
  • 260 bytes of receive buffering per active lwIP client
  • up to 256 bytes each for caller-owned RTU request and response buffers when maximum-size frames are supported

The exact flash and RAM totals depend on compiler settings, lwIP configuration, HAL, PHY driver, and the chosen STM32.

Security

Modbus TCP provides no authentication, confidentiality, or authorization. Do not expose port 502 directly to the public internet. Use network segmentation, firewall rules, a VPN, or a security gateway, and validate all hardware actions in the write hooks.

Troubleshooting

The host build passes, but the STM32 project does not compile.
Check that CubeMX generated lwIP raw-API headers, App/include is in the include path, and all required App/src files are part of the active target.

The server does not accept connections.
Verify PHY link status, MAC/PHY address configuration, IP address assignment, and that MX_LWIP_Process() runs continuously in no-RTOS projects.

Port 502 cannot be opened on a desktop.
Ports below 1024 may require elevated privileges. Use the included demo on port 1502 instead.

A client reports an illegal data address.
The requested address range exceeds the configured bank size. Remember that protocol addresses are zero-based.

License

MIT — see LICENSE.

About

Portable Modbus TCP server for STM32 Cortex-M4 with lwIP support, tests, and Make/CMake builds.

Resources

Stars

0 stars

Watchers

1 watching

Forks

Releases

Packages

Contributors

Languages